Overview
These LEN ground isolators use broadband high-pass filters to provide complete galvanic isolation of DC currents between two pieces of equipment, whilst permitting the full bandwidth of the SDI signal to pass, thus avoiding problems of signal distortion and operator shocks caused by a voltage difference.
This method out-performs broadband transformers for SDI signals. Both signal and ground paths between equipment are isolated, there is no distortion of the signal. They are suitable for ASI format.
These medical-grade isolators offer a higher breakdown voltage for medical-grade applications and are available both constructed in ABS boxes with mounting flanges and as ‘barrel’ versions, with or without a mounting flange.
Specifications
Bandwidth: 0.5 MHz to 1485 MHz, - 0.25dB
Breakdown Voltage: 4kV
Dimensions: 50 x 35 x 15 (l x w x h) mm excluding mounting flanges, 68mm length including flanges.
Weight: 32g.
Brochures
|
LEN LTD LHDGI03 DATASHEET 2020/05Tipo file: PDF N Pagine: 2 | Dimensioni: 66Kb Download |
Brochures
|
CANFORD 90-6157 PAGINAWEB CON PREZZI 2021/02Tipo file: PDF N Pagine: 1 | Dimensioni: 415Kb Download |